SINAMICS S120 built-in units Booksize format Basic Line Filters for Active Line Modules
Thông tin chi tiết về sản phẩm SINAMICS S120 built-in units > Booksize format > Basic Line Filters for Active Line Modules của SIEMENS
Basic Line Filter



Technical specifications for Booksize format

General technical specifications

Unless explicitly specified otherwise, the following technical specifications are valid for all components of the SINAMICS S120 booksize drive system.
 

Note:

When engineering the complete SINAMICS S120 drive, the system data of the associated Control Units, supplementary system components, DC link components and Sensor Modules must be taken into consideration.

Electrical specifications

Line voltage

380 ... 480 V 3 AC ±10 % (-15 % <1 min)

Line system configurations

Grounded TN/TT systems and non-grounded IT systems

Line frequency

47 ... 63 Hz

Electronics power supply

24 V DC -15 %/+20 %1), safety extra low-voltage (PELV/SELV)

Short-circuit current rating (SCCR)

(Short Circuit Current Rating)
according to UL 508C (up to 600 V)

1.1 ... 447 kW: 65 kA

Electromagnetic compatibility

According to EN 61800‑3

Second environment, Category C2/C3

For further information, see section Configuration notes

Overvoltage category

According to IEC/EN 61800‑5‑1

III

Mechanical specifications

Degree of protection

 

  • According to EN 60529

IP20

  • According to UL 508C/UL 61800‑5‑1

Open type

Protection class

 

  • Line circuits with protective conductor connection according to IEC 61800‑5‑1

I

  • Electronic circuits

Safety extra low-voltage PELV/SELV

Ambient conditions

 

Storage

Transport

Operation

In product packaging

In transport packaging

 

Climatic environmental conditions

Class 1K4
acc. to EN 60721‑3‑1
-25 ... +55 °C (-13 ... +131 °F)

Class 2K4
acc. to EN 60721‑3‑2
-40 ... +70 °C (-40 ...+158 °F)

Class 3K3 3)
acc. to EN 60721‑3‑3
For operation without derating4): 0 ... +40 °C (32 ...104 °F)
For operation with derating: >40 ... +55 °C (>104 ... 131 °F)

Relative humidity 5 ... 95 %

Environmental class/harmful chemical substances

Class 1C2
acc. to EN 60721‑3‑1

Class 2C2
acc. to EN 60721‑3‑2

Class 3C2
acc. to EN 60721‑3‑3

Organic/biological influences

Class 1B1
acc. to EN 60721‑3‑1

Class 2B1
acc. to EN 60721‑3‑2

Class 3B1
acc. to EN 60721‑3‑3

Pollution degree 2)

acc. to IEC/EN 61800‑5‑1

2

Installation altitude

 

  • Up to 1000 m (3281 ft) above sea level

Without derating

  • From 1000 m (3281 ft) up to 2000 m (6562 ft) )above sea level observe the derating characteristics
  • Reduction of the output current by 10 % per 1000 m (3281 ft) or
  • Reduction of the ambient temperature by 5 K per 1000 m (3281 ft)
  • From 2000 m (6562 ft) up to 4000 m (13123 ft) above sea level observe the derating characteristics

 

  • Power components
  • Reduction of the output current by 10 % per 1000 m (3281 ft) or
  • Reduction of the ambient temperature by 5 K per 1000 m (3281 ft)

and additionally:

  • Operation on line supply systems with grounded neutral point, or
  • Operation with an isolating transformer with secondary grounded neutral point
  • Control Units
  • Reduction of the ambient temperature by 5 K per 1000 m (3281 ft)

Mechanical strength

 

Storage

Transport

Operation

In product packaging

In transport packaging

 

Vibratory load

Class 1M2
acc. to EN 60721‑3‑1

Class 2M3
acc. to EN 60721‑3‑2

Class 3M1
acc. to EN 60721‑3‑3
Test valuesacc. to EN 60068‑2‑6 :
10 oscillations per axis in the range: 10 ... 57 Hz constant deflection 0.075 mm
57 ... 150 Hz constant acceleration 9.81 m/s2(1 × g)

Shock load

Class 1M2
acc. to EN 60721‑3‑1

Class 2M3
acc. to EN 60721‑3‑2

Class 3M1
acc. to EN 60721‑3‑3
Test valuesacc. to EN 60068‑2‑27 :
3 shocks per axis in both directions
Peak acceleration 49 m/s2 (5 × g); duration 30 ms

Certificates

Declarations of conformity

CE (Low Voltage, EMC and M​achinery Directive)

Certificates of suitability

cULus

 

1) When using a motor holding brake, restricted voltage tolerances (24 V ±10 %) might need to be taken into account.
 

2) The components must be protected against conductive pollution, e.g. by installing them in a control cabinet with degree of protection IP54 according to IEC 60529 or NEMA 12. If conductive pollution can be excluded at the installation site, a lower degree of cabinet protection is permissible.
 

3) Better than 3K3 through increased ruggedness regarding the temperature range and humidity. Oil mist, salt mist, ice formation, condensation, dripping water, spraying water, splashing water and water jets are not permitted.

4) Also carefully observe the permissible temperatures for the Control Unit and operator panel.
 

Chi tiết về sản phẩm SINAMICS S120 built-in units > Booksize format > Basic Line Filters for Active Line Modules

 

Overview

In conjunction with Active Interface Modules and a logically consistent configuration of the plant or system, line filters limit the interference conducted by the power modules to the limit values of Category C2 acc. to EN 61800‑3. Line filters are only suitable for direct connection to TN line systems.
 

Note:

According to product standard EN 61800‑3, RFI suppression commensurate with the relevant rated conditions must be provided and is a legal requirement in the EU (EMC Directive). Line filters and line reactors are required for this purpose. The use of line filters of other makes can lead to limit value violations, resonance, overvoltages and irreparable damage to motors or other equipment. The machine manufacturer must provide verification that the machinery to be operated with the drive products and the installed suppression elements, e.g. line filters, are CE-EMC-compliant.
 

Optional Basic Line Filters that are coordinated with the power ranges in booksize format are available for the SINAMICS S120 drive system.
 

Basic Line Filter

With the Basic Line Filters in combination with the Active Interface Modules, the limits for the interference voltages can be extended to Category C2 (EN 61800-3) or, retaining Category C3, longer total cable lengths are possible for the configuration.
 

Basic Line Filters are used on machines on which conducted interference emissions in the frequency range between 150 kHz and 30 MHz need to be damped in accordance with the requirements of CE-EMC legislation.
 

Technical specifications

Line voltage 380 ... 480 V 3 AC

Basic Line Filter

 

6SL3000-0BE21-6DA0

6SL3000-0BE23-6DA1

6SL3000-0BE25-5DA0

6SL3000-0BE28-0DA0

6SL3000-0BE31-2DA0

Rated current

A

36

74

105

132

192

Power loss

kW

0.016

0.02

0.043

0.056

0.073

Line supply/load connection

L1, L2, L3 / U, V, W

 

Screw terminals

Screw terminals

Screw terminals

Screw terminals

Screw terminals

  • Conductor cross-section

mm2

10

35

50

95

95

PE connection

 

M6 screw studs according to DIN 46234

M6 screw studs according to DIN 46234

M8 screw studs according to DIN 46234

M10 screw studs according to DIN 46234

M10 screw studs according to DIN 46234

Degree of protection

 

IP20

IP20

IP20

IP20

IP20

Dimensions

 

 

 

 

 

 

  • Width

mm (in)

50 (1.97)

75 (2.95)

100 (3.94)

150 (5.91)

150 (5.91)

  • Height

mm (in)

429 (16.89)

433 (17.05)

466 (18.35)

479 (18.86)

479 (18.86)

  • Depth

mm (in)

226 (8.90)

226 (8.90)

226 (8.90)

226 (8.90)

226 (8.90)

Weight, approx.

kg (lb)

5 (11.0)

7.5 (16.5)

11.5 (25.4)

17.5 (38.6)

18.5 (40.8)

Certificate of suitability

 

cURus

cURus

cURus

cURus

cURus

Suitable for Active Line Module in booksize format

Type

6SL3130-7TE21-6AA4

6SL3130-7TE23-6AA3

6SL3130-7TE25-5AA3

6SL3130-7TE28-0AA3

6SL3130-7TE31-2AA3

  • Rated power of the Active Line Module

kW (hp)

16 (18)

36 (40)

55 (60)

80 (100)

120 (150)

 